![]() ![]() RETPCT : Battery charge % required after power off to restore power HITRANS : Input line voltage above which UPS will switch to battery LOTRANS : Input line voltage below which UPS will switch to battery ![]() SENSE : Current UPS sensitivity setting for voltage fluctuationsĭWAKE : Time UPS waits after power off when the power is restoredĭSHUTD : Delay before UPS powers down after command receivedĭLOWBATT: Low battery signal sent when this much runtime remains MINLINEV: Min (observed) input line voltage since apcupsd started MAXLINEV: Maximum input line voltage since apcupsd started MAXTIME : Max battery runtime (TIMEOUT) after which system is shutdown MINTIMEL: Min battery runtime (MINUTES) required for system shutdown MBATTCHG: Min battery charge % (BCHARGE) required for system shutdown TIMELEFT: Remaining runtime left on battery as estimated by the UPS LOADPCT : Percentage of UPS load capacity used as estimated by UPSīCHARGE : Current battery capacity charge percentage ![]() Smart-UPS and Matrix-UPS (Smart Signalling) MASTERUPD : Last time the master sent an update to the slaveĮNDAPC : Date and time of status information was written STATUS : UPS status (online, charging, on battery etc) STARTTIME : Date and time apcupsd was started MODEL : UPS model derived from UPS information UPSNAME : UPS name from configuration file (dumb) or EEPROM (smart)ĬABLE : Cable type specified in the configuration file VERSION : apcupsd version number, date and operating system HOSTNAME: hostname of computer running apcupsd Set out below is a sample of the status output which may be generated for the specified UPS models.Īll models APC : version, number of records and number of bytes following DATE : Date and time of last update from UPS Model of UPS being used and, in some cases, the firmware version. Generally there is a single piece of information on each line of output. The status report output format is simple ASCII. In the /etc/apcupsd/nf configuration file so that the Network Information Server will be accessible. It is therefore necessary to have the following configuration directives: The default is 3551, the official port number assigned by IANA for theĪpcaccess uses apcupsd's inbuilt Network Information Server (NIS) - no relation to Sun's NIS/YP service - to obtain the current status informationįrom the UPS on the local or remote computer. : An optional port number where a hostname argument has been specified. An optional hostname which may be a bare machine name, fully qualified domain name or IP address. Thisproduces a full printout of the available status informationfor the associated UPS. Status An optional command, unless a hostname is also beingspecified. The network which is running apcuspd in NIS mode. It can access status information from any APC UPS attached to the localhost or attached to any computer on (APC) UPSes provided you have the apcupsd(8)ĭaemon installed, properly configured and running. Apcaccess - retrieve status information from apcupsd(8)Īpcaccess is a program which prints out the complete status of most American Power Conversion Corp. ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |